Hollow brick on its own insulates little. Here is how to choose a wall build-up that really protects against the heat, without compromising the seismic-resistant structure.

Published 16 November 2026 · 3 min read · SIGMA ICC, engineering consultancy

For a high-performance exterior wall in Morocco, the most common and safest solution is the double brick wall with insulation (polystyrene or mineral wool) in the central cavity. Monomur-type honeycomb clay blocks and aerated concrete insulate better than ordinary hollow brick and simplify laying, but their performance depends heavily on the thickness and the product. In all cases, the concrete columns and tie beams must be treated.

Common wall build-ups

Build-upInsulationRemarks
Single hollow brick + rendersLowThe most widespread, insufficient on an exposed façade
Double wall with air cavityMediumBetter than a single wall, but air alone insulates little if the cavity is ventilated or clogged with mortar
Double wall with insulation (4 to 8 cm)GoodProven solution, compatible with the concrete frame
Thick “monomur” honeycomb clay blockGood depending on productQuick to lay, thin joints; requires certified products and careful detailing
Aerated concreteGood depending on thicknessLight, easy to cut; suitable renders essential
External insulation on masonryVery goodAlso treats the thermal bridges at the columns

To compare, ask for the thermal resistance R (m².K/W) or the U-value (W/m².K) of the complete wall as stated by the manufacturer. The higher R is, the better the wall insulates.

What you need to know about thermal mass

In Marrakech, the difference between day and night temperatures is large. A heavy wall (solid brick, concrete) insulated on the outside stores the coolness of the night and dampens the heat of the day. A lightweight wall, or one insulated only from the inside, reacts more quickly to temperature changes. The ideal combines insulation with mass on the inner side of the insulation.

Structural precautions

  • Infill walls are not load-bearing, but they must be tied and connected to the frame in accordance with the RPS 2011 seismic regulation.
  • A thicker or heavier wall changes the loads on the beams and foundations: the BET needs to know.
  • Insulating blocks must be fixed according to the manufacturer's instructions, particularly for guardrail and window frame anchors.

And the RTCM?

The thermal building regulation (decree 2-13-874) sets requirements for exterior walls that vary according to the zone (Marrakech in zone 5) and the glazing ratio. A double wall with insulation generally makes it possible to meet them; the compliance calculation is carried out on the complete wall. See insulation and the RTCM and thermal bridges.

Cost and benefit. A double wall with insulation costs a little more than a single wall: a second row of bricks, the insulation and slightly less floor area. In return, the required air conditioning capacity and consumption fall, and summer comfort improves markedly in exposed rooms. Ask the contractor for a separate price for the insulated wall so that you can compare, and check on site that the insulation is continuous and not crushed.

The role of the engineering consultancy

The BET calculates the U-value of the proposed walls, checks compliance with the RTCM, incorporates the weight of the walls into the structural calculation and proposes junction details with the columns and slabs.

Frequently asked questions

Does hollow brick insulate well?

No: a single hollow brick with its renders insulates little; on an exposed façade, a double wall with insulation or external insulation is much more effective.

Double wall with an air cavity or with insulation?

With insulation: an air cavity alone insulates little, especially if it is ventilated or filled with mortar debris; 4 to 8 cm of insulation makes a marked difference to performance.

Is monomur suitable for Morocco?

It can be, if it is a certified product of sufficient thickness, laid according to the instructions, with the concrete columns and tie beams treated.

A project in the pipeline?

SIGMA ICC designs reinforced concrete, electrical, plumbing and HVAC systems and supervises sites for villas, riads, hotels and shops.

Sources : Guide technique de l'isolation thermique au Maroc.