Yes, a load-bearing wall can be opened up or removed, but only after a structural study that calculates the loads to be carried, sizes the replacement beam (reinforced concrete or steel) and checks its supports down to the foundations. The work is carried out under propping, by a qualified contractor. In Morocco, a structural alteration may also require a permit and, in a co-owned building, the agreement of the co-owners.
How do you know if a wall is load-bearing?
A wall is load-bearing if it supports a floor, a roof or another wall. In a recent villa with a concrete frame (columns and beams), most walls are simple infill; in an old house, a riad or a confined masonry building, thick walls are almost always load-bearing. The clues: thickness, central position, joists resting on it. Only the structural drawings or a survey can settle the matter.
The steps of an opening
- Survey and design: survey of the existing building, load take-down, choice of beam and supports, check of the foundations under the new support points.
- Permits: depending on the nature of the work and the municipality, application via the Rokhas platform; agreement of the co-owners in an apartment building.
- Propping: props and timber beams on both sides of the wall to relieve the floor during the work.
- Creating the supports: reinforced concrete columns or padstones at the ends of the opening.
- Installing the beam: reinforced concrete beam cast in place or steel section, packed and grouted onto its supports.
- Demolition of the wall under the beam, then removal of the props once the grout has hardened.
The risks of an improvised opening
- Cracking and sagging of the floor above if the beam is too weak or poorly packed.
- Bearing failure at the supports: a well-sized beam resting on fragile masonry crushes its support.
- Reduced seismic resistance: a load-bearing wall often contributes to bracing; removing it can make the building vulnerable to earthquakes, as the damage in Al Haouz showed.
- Inadequate foundations under the new columns, which concentrate the loads.
Concrete or steel?
A steel beam (IPN, IPE, HEA) is quick to install and limits the downstand, but must be protected against corrosion and sometimes against fire. A reinforced concrete beam, cast in place, requires formwork and a hardening period but integrates well into a concrete structure. The choice depends on the span, the acceptable downstand and site access.
The role of the engineering firm
The engineering firm carries out the survey, the design calculations and the construction drawings, then inspects the propping and the installation of the beam. It also checks the impact on the overall seismic stability, particularly in a vertical extension or a major renovation. Before buying a property to convert, a structural check avoids unpleasant surprises.
Frequently asked questions
Can a load-bearing wall be removed in a house?
Yes, provided a replacement beam and its supports are designed by a structural engineer and the work is carried out under propping.
Is a permit needed to open a load-bearing wall in Morocco?
A structural alteration may require a permit from the municipality, to be checked depending on the work, and the agreement of the co-owners in an apartment building.
What beam should replace a load-bearing wall?
A reinforced concrete beam or a steel section (IPN, IPE, HEA), whose size depends on the span and loads and must be set by the design calculations.
A project in the pipeline?
SIGMA ICC designs reinforced concrete, electrical, plumbing and HVAC systems and supervises sites for villas, riads, hotels and shops.
Sources : La Maison Saint-Gobain, ouvrir un mur porteur · Copeps, étapes d'une ouverture de mur porteur.