Le Noyer A, No. 23, 2nd floor, Ibn Sina, Guéliz, Marrakech +212 6 61 05 74 55 · +212 6 20 89 76 60 · sigma.icc@gmail.com

Retaining wall: design, drainage and mistakes to avoid

A retaining wall holds back tonnes of soil and often water. Poorly designed or poorly drained, it tips over or cracks: it is a structure that must be designed by calculation.

Published 16 November 2026 · 5 min read · SIGMA ICC, engineering consultancy

A retaining wall is designed on the basis of the earth pressure it retains, the surcharges (cars, buildings upslope) and the presence of water. The checks ensure that it does not overturn, does not slide, that the soil under its footing bears it and that the concrete and steel are strong enough. Insurers recommend a study by an engineering firm beyond 1.50 m of retained height, and drainage is as important as the calculation.

The forces involved

Earth pressure increases with depth: it is zero at the top of the wall and maximum at its base. It depends on the nature of the soil (density, friction angle, cohesion). A car parked at the top, a neighbouring house or a swimming pool add a surcharge. Above all, water building up behind an undrained wall adds hydrostatic pressure that can double the forces. In a seismic zone like Marrakech, earthquakes also increase the pressure.

The four checks

CheckRisk avoidedMeans
OverturningThe wall tips over downslopeWider footing, heel under the retained soil
SlidingThe wall slides on its baseShear key under the footing, wider footing
Soil bearing capacityThe soil gives way under the toe of the footingFooting sized from the soil investigation
Wall strengthThe stem cracks or failsCalculated thickness and reinforcement

Types of wall

  • Reinforced concrete "inverted T" wall: a stem fixed to a footing with a toe at the front and a heel under the retained soil. This is the most common solution for a villa.
  • Gravity wall in masonry, stone or unreinforced concrete: it resists through its mass, suitable for low heights.
  • Gabion or block walls: free-draining by nature, suitable for landscaping.

Drainage, the weak point of failed walls

A large share of retaining wall failures comes from poor water drainage. A well-designed wall includes:

  • A drainage layer of gravel behind the wall, separated from the soil by a geotextile.
  • A drain at the base, connected to an outlet.
  • Weep holes: pipes passing through the wall, sloping slightly downslope, which let the water out.
  • Waterproofing or a bituminous coating on the face against the soil if the wall borders a room.

Weep holes and drains must be maintained: when blocked, they leave the wall as vulnerable as if it had none.

The role of the engineering firm

The engineering firm relies on the soil investigation to design the wall, and provides the formwork and reinforcement drawings and the drainage details. For a basement, the retaining wall is also the wall of the room: see our article on basement tanking.

Frequently asked questions

From what height should a retaining wall be designed by an engineer?

Insurers recommend a study by an engineering firm beyond 1.50 m of retained soil, and whenever there is a surcharge upslope or water.

What are weep holes for?

They are pipes passing through the wall that drain the water building up behind it; without them, the water pressure adds to the earth pressure.

Why does a retaining wall tip over?

Most often because of a footing that is too narrow, an unforeseen surcharge, or missing or blocked drainage that lets water push on the wall.

A project in the pipeline?

SIGMA ICC designs reinforced concrete, electrical, plumbing and HVAC systems and supervises sites for villas, riads, hotels and shops.

Sources : AQC, murs de soutènement, bonnes pratiques · SMABTP, fiche pathologie mur de soutènement · Université de Tlemcen, cours sur les soutènements.

Can we help you?

Click to call, or write to us: we answer 7 days a week for emergencies.

Chat on WhatsApp