According to the NF C 15-100 table (2002 edition as amended, still widely applied), a dwelling of 35 m² or less has at least 2 30 mA residual current switches, a dwelling of 35 to 100 m² has 3, and a dwelling of more than 100 m² has 4, each time including one type A for the hob and the washing machine. For a villa, this minimum is almost always exceeded, because the number of circuits is what decides.
The reference table
| Floor area of the dwelling | Type AC residual current switches | Type A residual current switch |
|---|---|---|
| 35 m² or less | 1 × 25 A | 1 × 40 A |
| From 35 to 100 m² | 2 × 40 A | 1 × 40 A |
| More than 100 m² | 3 × 40 A | 1 × 40 A |
These values are minimums for a standard dwelling. The 2024 edition of the standard reorganised these rules: depending on the edition applied to your project, the engineering firm or the inspection body specifies the exact requirements, particularly regarding types A and F.
Why several residual current devices
- Avoid cutting everything: if a single residual current device protects the whole house, a leak on a garden socket plunges the villa into darkness.
- Limit cumulative leakage: each appliance leaks a few milliamps. Too many appliances under the same 30 mA device cause nuisance tripping.
- Split lighting and sockets: the lighting circuits of a given zone are placed under different residual current devices from the sockets, so that some light remains in the event of a fault.
Manufacturers advise not to exceed about 8 circuits per residual current switch. In a heavily equipped villa (air conditioning, IT, LED lighting with electronic drivers), it is prudent to stay below that, as each piece of electronic equipment adds a small permanent leakage current.
Example for a 250 m² villa in Marrakech
- Type A residual current device no. 1: hob, washing machine, dishwasher.
- Type F residual current devices (one or two): inverter air conditioners, variable-speed pool pump.
- Type AC or A residual current devices (three or four): lighting and sockets, distributed by floor or by zone (day, night, outdoors).
- Separate residual current device for the freezer and, if needed, for the IT network and video surveillance.
This often results in 6 or 8 residual current devices, well beyond the minimum of 4. In three-phase, the residual current devices are also used to balance the load between the three phases.
The role of the engineering firm
The engineering firm counts the circuits, chooses the type and rating of each residual current device, checks that the sum of the downstream circuits remains compatible with its rating, and provides spare capacity in the board (see distribution board and GTL). For choosing the type, read 30 mA RCD type AC, A or F.
Frequently asked questions
How many RCDs for a 120 m² house?
The NF C 15-100 table (2002 edition) requires at least 4 30 mA residual current switches above 100 m²: three type AC rated 40 A and one type A rated 40 A.
How many circuits under one residual current switch?
Manufacturers advise a maximum of about 8 circuits per residual current switch, to limit cumulative leakage currents and nuisance tripping.
Is a type A residual current device mandatory?